As 10 pipe markers process labeling banner thumb
AS-10
Vinyl Tapes and Markers
Econimical solution for indoor and outdoor installations. Service temperature: ‑40°C to +80°C. Service lifetime: 3-8 years

AS-10 Vinyl Tapes and Markers

Dedicated for indoor and outdoor use in areas with limited exposure to direct sunlight and difficult weather conditions. It offers fair durability, good flexibility and limited temperature resistance. Equipped with pressure sensitive acrylic adhesive and protective release liner. Recommended for newly installed pipes. It is our most economical solution for pipeline identification.

Durable vinyl (PVC) self-adhesive tapes make pipe content and flow information highly visible. Markers meet ISO 14726 standard.

Compare markers

Technical details

Service temperature -40°C to 80°C
Surface preparation Yes
Mounting method Self-adhesive
UV resistance Good
Weather resistance Very Good
Chemical resistance Good
Sea water resistance Yes
Reuse after removing No
Service lifetime* 3-8 years

* The actual lifetime of the markers depends on the particular conditions of use. Please contact our specialists for more information.

Availability

AS-10 sample roll AS-10 sample marker
rolls markers
AS-10 General picture

Features

  • fair resistance to weather conditions and UV rays
  • economic and easy to use
  • no minimum quantity
  • custom production with any texts and graphics
  • high quality acrylic adhesive

Design and dimensions

A-SPE Pipemarking Tapes and Markers can be produced in accordance to the particular requirements of our customers. According to the request they can be designed to comply with one of the following regulations:

  • ISO 14726:2008
  • BS-1710 / BS-4800
  • ANSI/ASME A13-1
  • TRGS-201
ISO 14726 samples ANSI ASME A13.1 samples TRGS-201 samples


A-SPE Tapes and Markers can be printed in any language based on the translation provided by the customer.

Each pipe marker is dedicated for particular pipe diameter. Below table shows recommended markers dimensions for most popular nominal pipe sizes. Adjusted marker length is always followed by suitable font and arrow size.

Below sizes consider minimum 30mm overlap, however they do not consider any additional pipe coatings like insulations etc. The information about insulation thickness or other coating should be provided with other details necessary for the quotation.

DN - Nominal Pipe DiameterPipe Diameter (inch)Length of the marker (mm)Letter height (mm)Arrow hieght (mm)
DN15 1/2" 100 6,5 16
DN20 3/4" 115 13 16
DN25 1" 135 13 16
DN32 1 1/4" 165 19 19
DN40 1 1/2" 190 19 19
DN50 2" 230 19 19
DN65 2 1/2" 270 32 32
DN80 3" 320 32 32
DN100 4" 395 32 32
DN150 6" 580 32 32
DN200 8" 760 32 32
DN250 10" 945 32 32
DN300 12" 1120 32 32
DN350 14" 1230 32 32
DN400 16" 1400 32 32
DN450 18" 1580 32 32
DN500 20" 1750 32 32
DN600 24" 2100 32 32
DN700 28" 2400 32 32
DN750 30" 2550 32 32
DN900 36" 3050 32 32
DN1100 44" 3700 32 32
DN1200 48" 4050 32 32

Installation tips

Important: During application the tape should overlap 2-3 cm

According to the ISO 14726:2008 regulation the following advises shall be considered during the pipe markers and tapes installation:

  1. The markers should be installed within a distance of 3-5 meters of the length of the horizontal and straight pipelines, whereby the local conditions may require a more frequent marking due to pipe bends or the close proximity of pipes for different services.
  2. In case of the system valves the markers should be installed in a distance of approximately 75mm from the corresponding flange.
  3. The markers should appear at each penetration point in bulkheads, walls or decks.
  4. In areas with the piping system junctions the markers should be installed on each side of the junction.
  5. In case of the vertical piping system the markers should be applied on height of approximately 170cm to ensure good visibility at eye level of the observing persons.

The exact estimation of the amount of markers and installation points is determined during the material take-off process. A-SPE specialists can offer you a professional consulting on base of the provided pipe lines schemes and detailed specification.

Process labeling tips

Identification colours

Basic identification tapes (acc. to ISO 14726:2008):
Description Type Ordering code ISSA IMPA
Waste media a

Black (RAL 9005, HKS 88 K)

SC40 47.521.40 33.2140
Fresh water

Blue (RAL 5015)

SC41 47.521.41 33.2141
Fuel

Brown (RAL 8001)

SC42 47.521.42 33.2142
Sea Water b

Green (RAL 6018)

SC43 47.521.43 33.2143
Non-flammable Gases

Grey (RAL 7001)

SC44 47.521.44 33.2144
Air and sounding pipes

Maroon (RAL 8015, HKS 18 K)

SC45 47.521.45 33.2145
Oil other than fuels

Orange (RAL 2003)

SC46 47.521.46 33.2146
Steam

Silver (RAL 9006)

SC47 47.521.47 33.2147
Fire fighting

Red (RAL 3000, HKS 15 K)

SC48 47.521.48 33.2148
Acids & Alkalis

Violet (RAL 4001, HKS 34 K)

SC49 47.521.49 33.2149
Air in ventilation systems

White (RAL 9010)

SC50 47.521.50 33.2150
Flammable gases

Yellow-ochre (RAL 1021, HKS 4 K)

SC51 47.521.51 33.2151
Flow direction marking

 

SC30 47.521.30 33.2130

a Examples: black water, grey water, waste oil, exhaust gas.

b For ships with mixed navigation (sea-river) ships: all outside waters.


Multi-colour permutations (acc. to ISO 14726:2008):
Description Colour identification Ordering code
Waste media
     
SC40
Black water
     
MC40‑41
Waste oil / Used oil
     
MC40‑42
Bilge water
     
MC40‑43
Exhaust gas
     
MC40‑44
Grey water
     
MC40‑50
Sewage - contaminated
   
MC40‑51
Fresh water
   
SC41
Fresh water, sanitary
   
MC41‑42
Potable water
   
MC41‑43
Distillate
   
MC41‑44
Gas turbine wash water
   
MC41‑46
Feed water
   
MC41‑47
Cooling fresh water
   
MC41‑49
Chilled water
   
MC41‑50
Condensate
   
MC41‑51
Sea water
   
SC43
Decontamination water
   
MC43‑41
Sea water, sanitary
   
MC43‑42
Ballast water
   
MC43‑49
Cooling sea water
   
MC43‑51
Fuel
   
SC42
Heavy fuel oil (HFO)
   
MC42‑40
Aviation fuel
   
MC42‑41
Biological fuel
   
MC42‑49
Gas-turbine fuel
   
MC42‑50
Marine diesel fuel (MDO)
   
MC42‑51
Non-Flammable gases
   
SC44
Oxygen
   
MC44‑41
Inert gas
   
MC44‑42
Nitrogen
   
MC44‑43
Refrigerant
   
MC44‑45
Compressed air LP (low pressure)
   
MC44‑46
Compressed air HP (high pressure)
   
MC44‑48
Control air / Regulating air
   
MC44‑49
Breathing air*
   
MC44‑50
Breathing gas*
   
MC44‑51
Description Colour identification Ordering code
Air and sounding pipes
   
SC45
Waste media
   
MC45‑40
Fresh water
   
MC45‑41
Fuel
   
MC45‑42
Sea water
   
MC45‑43
Non-flammable gases
   
MC45‑44
Oil other than fuels
   
MC45‑46
Steam
   
MC45‑47
Fire fighting
   
MC45‑48
Acids, alkalis
   
MC45‑49
Ventilation system
   
MC45‑50
Flammable gases
   
MC45‑51
Oil other than fuels
   
SC46
Thermal fluid
   
MC46‑41
Lubricaition oil for gas turbines
   
MC46‑43
Hydraulic fluid
   
MC46‑44
Lubricaition oil for steam turbines
   
MC46‑47
Lubricaition oil for gears
   
MC46‑49
Lubrication oil for int. combustion engines
   
MC46‑51
Steam
   
SC47
Steam for heating purposes
   
MC47‑40
Driving steam
   
MC47‑43
Exhaust steam
   
MC47‑50
Supply steam
   
MC47‑51
Acids & Alkalis
   
SC49
Air in ventilation systems
   
SC50
Discharge air
   
MC50‑40
Mechanical supply air - cold
   
MC50‑41
Natural exhaust air
   
MC50‑42
Atmospheric air
   
MC50‑43
Mechanical exhaust air
   
MC50‑44
Decontaminated supply air
   
MC50‑45
Mechanical recirculated air
   
MC50‑46
Mechanical supply air - warm
   
MC50‑47
Smoke clearance
   
MC50‑48
Conditioned supply air
   
MC50‑49
Natural supply air
   
MC50‑51
Fire fighting / Fire protection
   
SC48
Fire-fighting water
   
MC48‑43
Fire-fighting gas
   
MC48‑44
Sprinkler water
   
MC48‑46
Spray water
   
MC48‑49
Fire-fighting powder
   
MC48‑50
Fire-fighting foam
   
MC48‑51
Flammable gases
   
SC51
Hydrogen
   
SC51‑41
Acetylene
   
SC51‑44
Liquid gas
   
SC51‑49

* Intended for use in submarines for distribution systems used for breathing air from cylinders.

Quotation
Close

We are using cookies to ensure functionality of this website and to gather visitor statistics for internal use only.
If you do not block these files, it means that you agree to save cookies in cache of your web browser.
You can change your cookie settings at any time. Otherwise, we'll assume you're OK to continue.