Safety Marking Tapes
IMO Pipemarking Tapes - Marine Pipe Identification Tape - acc to ISO 14726
General Description
Pipeline identification on board ships is very important for safety reasons, especially for the safety of the entire crew. The medium flowing through the the pipework can cause a lot of damage, and be dangerous to the people on board the ship during an emergency or in case of pipework damage. The appropriate marking makes it possible to identify the type of danger we are dealing with during the emegency and to take the steps to get rid of it.

The International ISO14726-1 (year 1999) standard defines the basic colours which should be used for pipeline identification on board ships.
Another regulation, ISO 1476-2 (year 2002) specifies additional colours which can be used together with the main colours for a more thorough marking of the medium flowing through the pipework.
The table included in this broshure presents the basic colours and also all the available permutations of identification colours in accordance with the ISO14726-2 (year 2002) norms.
Availability
The identification tapes are available in two systems:
Multi-colour system - tapes with the colour combination printed on it - this system is the easiest to install.
Single-colour system - tapes from which you can make any number of colour combinations by yourself, this is a more economical and flexible solution, however, the installation takes longer to complete.
All types of tapes are available at following standard sizes:
40 mm x 25 m
70 mm x 25 m
160 mm x 25 m
Considering many size standards available on the market we can manufacture any particular size for you.
Installation
- Each pipe should be marked at least once in each separate room.
- The best places for installing the identification tapes are: close to the objects like valves, filters or tanks, exits passing through the walls or cellings, close to the room entrances.
- All surfaces must be thoroughly cleaned before applying the identification tapes.
- During the application tape should be overlaped 3-4 cm beyond the starting edge.
Basic identification tapes (acc to ISO14726-1):
| Type | Description | Ordering code | ISSA Ref. Nos. | |
![]() |
Waste media Fresh water Fuel Sea Water Non-flammable Gases Masses Oil other than fuel Steam Fire fighting Acids & Alkalis Air in ventilation systems Flammable gases Flow direction marking |
SC40 SC41 SC42 SC43 SC44 SC45 SC46 SC47 SC48 SC49 SC50 SC51 SC30 |
47.521.40 47.521.45 47.521.42 47.521.44 47.521.47 47.521.43 47.521.41 47.521.49 47.521.48 47.521.46 47.521.51 47.521.50 47.521.30 |
Multi-colour permuations (acc to ISO14726-2):
| Description | Colour identification |
Ordering code | ISSA Ref. Nos. | ||
| Multi-colour | Single-colour | ||||
| Waste media Black water Waste oil / Used oil Bilge water Exhaust gas Grey water Sewage - contaminated |
![]() |
SC40 MC40-41 MC40-42 MC40-43 MC40-44 MC40-50 MC40-51 |
SC40 SC40+SC41+SC40 SC40+SC42+SC40 SC40+SC43+SC40 SC40+SC44+SC40 SC40+SC50+SC40 SC40+SC51+SC40 |
47.521.40 47.521.40 - 47.521.41 - 47.521.40 47.521.40 - 47.521.42 - 47.521.40 47.521.40 - 47.521.43 - 47.521.40 47.521.40 - 47.521.44 - 47.521.40 47.521.40 - 47.521.50 - 47.521.40 47.521.40 - 47.521.51 - 47.521.40 |
|
| Fresh water Fresh water, sanitary Potable water Distillate Gas turbine wash water Feed water Cooling fresh water Chilled water Condensate |
![]() |
SC41 MC41-42 MC41-43 MC41-44 MC41-46 MC41-47 MC41-49 MC41-50 MC41-51 |
SC41 SC41+SC42+SC41 SC41+SC43+SC41 SC41+SC44+SC41 SC41+SC46+SC41 SC41+SC47+SC41 SC41+SC49+SC41 SC41+SC50+SC41 SC41+SC51+SC41 |
47.521.41 47.521.41 - 47.521.42 - 47.521.41 47.521.41 - 47.521.43 - 47.521.41 47.521.41 - 47.521.44 - 47.521.41 47.521.41 - 47.521.46 - 47.521.41 47.521.41 - 47.521.47 - 47.521.41 47.521.41 - 47.521.49 - 47.521.41 47.521.41 - 47.521.50 - 47.521.41 47.521.41 - 47.521.51 - 47.521.41 |
|
| Sea water Decontamination water Sanitary sea water Ballast water Cooling sea water |
![]() |
SC43 MC43-41 MC43-42 MC43-49 MC43-51 |
SC43 SC43+SC41+SC43 SC43+SC42+SC43 SC43+SC49+SC43 SC43+SC51+SC43 |
47.521.43 47.521.43 - 47.521.41 - 47.521.43 47.521.43 - 47.521.42 - 47.521.43 47.521.43 - 47.521.49 - 47.521.43 47.521.43 - 47.521.51 - 47.521.43 |
|
| Fuel HFO (Heavy fuel oil) Aviation fuel Biological fuel Gas-turbine fuel MDO (Marine diesel fuel) |
![]() |
SC42 MC42-40 MC42-41 MC42-49 MC42-50 MC42-51 |
SC42 SC42+SC40+SC42 SC42+SC41+SC42 SC42+SC49+SC42 SC42+SC50+SC42 SC42+SC51+SC42 |
47.521.42 47.521.42 - 47.521.40 - 47.521.42 47.521.42 - 47.521.41 - 47.521.42 47.521.42 - 47.521.49 - 47.521.42 47.521.42 - 47.521.50 - 47.521.42 47.521.42 - 47.521.51 - 47.521.42 |
|
| Non-Flammable gases Oxygen Inert gas Nitrogen Refrigerant Compressed air LP Compressed air HP Control air / Regulating air Breathing air* Breathing gas* |
![]() |
SC44 MC44-41 MC44-42 MC44-43 MC44-45 MC44-46 MC44-48 MC44-49 MC44-50 MC44-51 |
SC44 SC44+SC41+SC44 SC44+SC42+SC44 SC44+SC43+SC44 SC44+SC45+SC44 SC44+SC46+SC44 SC44+SC48+SC44 SC44+SC49+SC44 SC44+SC50+SC44 SC44+SC51+SC44 |
47.521.44 47.521.44 - 47.521.41 - 47.521.44 47.521.44 - 47.521.42 - 47.521.44 47.521.44 - 47.521.43 - 47.521.44 47.521.44 - 47.521.45 - 47.521.44 47.521.44 - 47.521.46 - 47.521.44 47.521.44 - 47.521.48 - 47.521.44 47.521.44 - 47.521.49 - 47.521.44 47.521.44 - 47.521.50 - 47.521.44 47.521.44 - 47.521.51 - 47.521.44 |
|
| Masses | SC45 | SC45 | 47.521.45 | ||
| Oil other than fuel Thermal fluid Lubricaition oil for gas turbines Hydraulic fluid Lubricaition oil for steam turbines Lubricaition oil for gears Lub. Oil for int. combustion engines |
![]() |
SC46 MC46-41 MC46-43 MC46-44 MC46-47 MC46-49 MC46-51 |
SC46 SC46+SC41+SC46 SC46+SC43+SC46 SC46+SC44+SC46 SC46+SC47+SC46 SC46+SC49+SC46 SC46+SC51+SC46 |
47.521.46 47.521.46 - 47.521.41 - 47.521.46 47.521.46 - 47.521.43 - 47.521.46 47.521.46 - 47.521.44 - 47.521.46 47.521.46 - 47.521.47 - 47.521.46 47.521.46 - 47.521.49 - 47.521.46 47.521.46 - 47.521.51 - 47.521.46 |
|
| Steam Steam for heating purposes Exhaust steam Supply steam |
![]() |
SC47 MC47-40 MC47-50 MC47-51 |
SC47 SC47+SC40+SC47 SC47+SC50+SC47 SC47+SC51+SC47 |
47.521.47 47.521.47 - 47.521.40 - 47.521.47 47.521.47 - 47.521.50 - 47.521.47 47.521.47 - 47.521.51 - 47.521.47 |
|
| Acids & Alkalis | SC49 | SC49 | 47.521.49 | ||
| Air in ventilation systems Discharge air Mechanical supply air - cold Mechanical supply air Atmospheric air Mechanical exhaust air Decontaminated supply air Mechanical recirculated air Mechanical supply air - warm Smoke clearance Conditioned supply air Natural supply air |
![]() |
SC50 MC50-40 MC50-41 MC50-42 MC50-43 MC50-44 MC50-45 MC50-46 MC50-47 MC50-48 MC50-49 MC50-51 |
SC50 SC50+SC40+SC50 SC50+SC41+SC50 SC50+SC42+SC50 SC50+SC43+SC50 SC50+SC44+SC50 SC50+SC45+SC50 SC50+SC46+SC50 SC50+SC47+SC50 SC50+SC48+SC50 SC50+SC49+SC50 SC50+SC51+SC50 |
47.521.50 47.521.50 - 47.521.40 - 47.521.50 47.521.50 - 47.521.41 - 47.521.50 47.521.50 - 47.521.42 - 47.521.50 47.521.50 - 47.521.43 - 47.521.50 47.521.50 - 47.521.44 - 47.521.50 47.521.50 - 47.521.45 - 47.521.50 47.521.50 - 47.521.46 - 47.521.50 47.521.50 - 47.521.47 - 47.521.50 47.521.50 - 47.521.48 - 47.521.50 47.521.50 - 47.521.49 - 47.521.50 47.521.50 - 47.521.51 - 47.521.50 |
|
| Fire fighting / Fire protection Fire-fighting water Fire-fighting gas Sprinkler water Spray water Fire-fighting powder Fire-fighting foam |
![]() |
SC48 MC48-43 MC48-44 MC48-46 MC48-49 MC48-50 MC48-51 |
SC48 SC48+SC43+SC48 SC48+SC44+SC48 SC48+SC46+SC48 SC48+SC49+SC48 SC48+SC50+SC48 SC48+SC51+SC48 |
47.521.48 47.521.48 - 47.521.43 - 47.521.48 47.521.48 - 47.521.44 - 47.521.48 47.521.48 - 47.521.46 - 47.521.48 47.521.48 - 47.521.49 - 47.521.48 47.521.48 - 47.521.50 - 47.521.48 47.521.48 - 47.521.51 - 47.521.48 |
|
| Flammable gases Hydrogen Acetylene Liquid gas |
![]() |
SC51 SC51-41 SC51-44 SC51-49 |
SC51 SC51+SC41+SC51 SC51+SC44+SC51 SC51+SC49+SC51 |
47.521.51 47.521.51 - 47.521.41 - 47.521.51 47.521.51 - 47.521.44 - 47.521.51 47.521.51 - 47.521.49 - 47.521.51 |
|
* Intended for use in submarines for distribution systems used for breathing air from cylinders.
Technical specification:
- Thickness (average): 80 microns (without protective paper and adhesive)
- Dimensional stability: (FINAT TM 14) adhered to steel, no measurable shrinkage in cross irections, in length 0,44 m max
- Temperatur resistance: adhered to aluminum -40C to 80C, no variation
- Water resistance: adhered to aluminum, after 48h / 23C, no variation
- Adhesive power: 16 N / 25 mm (FINAT TM 1, after 24h, stainless steel)
- Tensile strength: (DIN EN ISO 527) along - min. 19 Mpa, across - min. 19 Mpa
- Elongation at break: (DIN EN ISO 527) along - min. 130%, across - min. 150%
- Shelf life: 2 years (in original packaging, at 20C and 50% relative humidity)
- Application temperature: min. +10C
- Service life by specialist application: 3 years (depending on individual use conditions)